Press Ceramics: Setting Variables Per Cycle

  F 1 T1 Start Temperature: it is the temperature from which a press-injection cycle starts. When you start the programme the oven raises its inner Temperature up to the T1. When such temperature is reached the oven will give a sound signal to indicate that it is ready for the cylinder. The user must open manually the oven, place the cylinder, close again the oven with the arrows and the cycle will continue F 2 t 2 Injection temperature: it is the Temperature the oven will reach to obtain the softening of the “rough” and proceed with the...

Continue reading

Normal Ceramic: Setting Variables Per Cycle

  F 1 ta Drying Temperature (or starting temperature) from 20° to 1200° Celsius. This temperature is obtained with a fixed slawe rate of 70°C/min F 2 t1 Drying Time or Muffle closing time (minutes and seconds). Once the Drying Temperature TA is reached, the plate will lift itself and according to the set value of this variable will close the muffle F 3 t2 Drying Time with closed muffle before the firing begins (in minutes and seconds). This time can be important to balance the inner muffle temperature after this has closed. If you set 0, after having closed the muffle the oven will...

Continue reading

Technical Specifications

Power Supply 230 V – 50/60 Hz Power (no pump) 1.200 w Fuses 10A Dimensions Cm 395x450x530 Weight Kg. 29 Available programmes 100 (80+20) Functions (variables) per normal ceramic programme 15 Functions (variables) per injection ceramic programme 14 Max. Temperature 1.200 °C Selfcalibration programme YES

Continue reading

Where we are
Sirio Dental srl
via A. Accardi 11
47014 Meldola (FC)
Italy
Contacts

This email address is being protected from spambots. You need JavaScript enabled to view it.
tel +39 0543 490327
fax +39 0543 499126


© 2022 - Sirio Dental division. All rights reserved.
Project by oraziofabbri.